MIB Browser

HC-ALARM-MIB

Standards (IETF)
This module defines Remote Monitoring MIB extensions for
High Capacity Alarms.

Copyright (C) The Internet Society (2002). This version
of this MIB module is part of RFC 3434; see the RFC
itself for full legal notices.
Organization
Netgear Inc
Root OID
1.3.6.1.2.1.16.29
Last updated
Objects
37
Source
Show full MIB
snmptranslate -m HC-ALARM-MIB -Tp
snmpwalk -v2c -c <community> -m HC-ALARM-MIB <host> 1.3.6.1.2.1.16.29

Imports

HCNUM-TCCounterBasedGauge64
RMON-MIBOwnerString, rmon, rmonEventGroup
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIBits, Counter32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso
SNMPv2-TCDisplayString, PhysAddress, RowStatus, StorageType, TEXTUAL-CONVENTION, VariablePointer

OID tree

NameOIDTypeAccessStatusExample
IhcAlarmMIB1.3.6.1.2.1.16.29
NhcAlarmObjects1.3.6.1.2.1.16.29.1
NhcAlarmControlObjects1.3.6.1.2.1.16.29.1.1
ThcAlarmTable1.3.6.1.2.1.16.29.1.1.1NA
RhcAlarmEntry1.3.6.1.2.1.16.29.1.1.1.1NA
ChcAlarmIndex1.3.6.1.2.1.16.29.1.1.1.1.1Integer32 (1..65535)NA
ChcAlarmInterval1.3.6.1.2.1.16.29.1.1.1.1.2Integer32 (1..2147483647)RC
ChcAlarmVariable1.3.6.1.2.1.16.29.1.1.1.1.3VariablePointerRC
ChcAlarmSampleType1.3.6.1.2.1.16.29.1.1.1.1.4INTEGERRC
ChcAlarmAbsValue1.3.6.1.2.1.16.29.1.1.1.1.5CounterBasedGauge64RO
ChcAlarmValueStatus1.3.6.1.2.1.16.29.1.1.1.1.6HcValueStatusRO
ChcAlarmStartupAlarm1.3.6.1.2.1.16.29.1.1.1.1.7INTEGERRC
ChcAlarmRisingThreshAbsValueLo1.3.6.1.2.1.16.29.1.1.1.1.8Unsigned32RC
ChcAlarmRisingThreshAbsValueHi1.3.6.1.2.1.16.29.1.1.1.1.9Unsigned32RC
ChcAlarmRisingThresholdValStatus1.3.6.1.2.1.16.29.1.1.1.1.10HcValueStatusRC
ChcAlarmFallingThreshAbsValueLo1.3.6.1.2.1.16.29.1.1.1.1.11Unsigned32RC
ChcAlarmFallingThreshAbsValueHi1.3.6.1.2.1.16.29.1.1.1.1.12Unsigned32RC
ChcAlarmFallingThresholdValStatus1.3.6.1.2.1.16.29.1.1.1.1.13HcValueStatusRC
ChcAlarmRisingEventIndex1.3.6.1.2.1.16.29.1.1.1.1.14Integer32 (0..65535)RC
ChcAlarmFallingEventIndex1.3.6.1.2.1.16.29.1.1.1.1.15Integer32 (0..65535)RC
ChcAlarmValueFailedAttempts1.3.6.1.2.1.16.29.1.1.1.1.16Counter32RO
ChcAlarmOwner1.3.6.1.2.1.16.29.1.1.1.1.17OwnerStringRC
ChcAlarmStorageType1.3.6.1.2.1.16.29.1.1.1.1.18StorageTypeRC
ChcAlarmStatus1.3.6.1.2.1.16.29.1.1.1.1.19RowStatusRC
NhcAlarmCapabilitiesObjects1.3.6.1.2.1.16.29.1.2
ShcAlarmCapabilities1.3.6.1.2.1.16.29.1.2.1BitsRO80
NhcAlarmNotifications1.3.6.1.2.1.16.29.2
NhcAlarmNotifPrefix1.3.6.1.2.1.16.29.2.0
!hcRisingAlarm1.3.6.1.2.1.16.29.2.0.1
!hcFallingAlarm1.3.6.1.2.1.16.29.2.0.2
NhcAlarmConformance1.3.6.1.2.1.16.29.3
NhcAlarmCompliances1.3.6.1.2.1.16.29.3.1
MhcAlarmCompliance1.3.6.1.2.1.16.29.3.1.1
NhcAlarmGroups1.3.6.1.2.1.16.29.3.2
GhcAlarmControlGroup1.3.6.1.2.1.16.29.3.2.1
GhcAlarmCapabilitiesGroup1.3.6.1.2.1.16.29.3.2.2
GhcAlarmNotificationsGroup1.3.6.1.2.1.16.29.3.2.3

Textual conventions

HcValueStatus INTEGER

valueNegative(3) valueNotAvailable(1) valuePositive(2)

This data type indicates the validity and sign of the data
in associated object instances which represent the absolute
value of a high capacity numeric quantity.  Such an object
may be represented with one or more object instances. An
object of type HcValueStatus MUST be defined within the same
structure as the object(s) representing the high capacity
absolute value.

If the associated object instance(s) representing the high
capacity absolute value could not be accessed during the
sampling interval, and is therefore invalid, then the
associated HcValueStatus object will contain the value
'valueNotAvailable(1)'.

If the associated object instance(s) representing the high
capacity absolute value are valid and actual value of the
sample is greater than or equal to zero, then the associated
HcValueStatus object will contain the value
'valuePositive(2)'.

If the associated object instance(s) representing the high
capacity absolute value are valid and the actual value of
the sample is less than zero, then the associated
HcValueStatus object will contain the value
'valueNegative(3)'.  The associated absolute value should be
multiplied by -1 to obtain the true sample value.

Traps / Notifications

Groups and compliance