MIB Browser

ENERGY-OBJECT-MIB

Standards (IETF)
Copyright (c) 2015 IETF Trust and the persons identified as
authors of the code.  All rights reserved.

Redistribution and use in source and binary forms, with or
without modification, is permitted pursuant to, and subject
to the license terms contained in, the Simplified BSD License
set forth in Section 4.c of the IETF Trust's Legal Provisions
Relating to IETF Documents
(http://trustee.ietf.org/license-info).

This MIB is used to monitor power and energy in
devices.

The tables eoMeterCapabilitiesTable and eoPowerTable
are a sparse extension of the eoTable from the
ENERGY-OBJECT-CONTEXT-MIB.  As a requirement,
[RFC7461] SHOULD be implemented.

Module Compliance of ENTITY-MIB v4 with respect to
entity4CRCompliance MUST be supported which requires
implementation of 4 MIB objects: entPhysicalIndex,
entPhysicalClass, entPhysicalName and entPhysicalUUID.
Organization
IETF EMAN Working Group
Root OID
1.3.6.1.2.1.229
Last updated
Objects
60
Source
Show full MIB
snmptranslate -m ENERGY-OBJECT-MIB -Tp
snmpwalk -v2c -c <community> -m ENERGY-OBJECT-MIB <host> 1.3.6.1.2.1.229

Imports

ENTITY-MIBentPhysicalIndex
IANAPowerStateSet-MIBPowerStateSet
RMON-MIBOwnerString
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIBits, Counter32, Integer32, IpAddress, MODULE-IDENTITY, MibIdentifier, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso, mib-2
SNMPv2-TCDisplayString, PhysAddress, RowStatus, StorageType, TEXTUAL-CONVENTION, TimeInterval, TimeStamp, TruthValue

OID tree

NameOIDTypeAccessStatusExample
IenergyObjectMib1.3.6.1.2.1.229
NenergyObjectMibNotifs1.3.6.1.2.1.229.0
SeoPowerEnableStatusNotification1.3.6.1.2.1.229.0.1TruthValueRW1
!eoPowerStateChange1.3.6.1.2.1.229.0.2
NenergyObjectMibObjects1.3.6.1.2.1.229.1
TeoMeterCapabilitiesTable1.3.6.1.2.1.229.1.1NA
ReoMeterCapabilitiesEntry1.3.6.1.2.1.229.1.1.1NA
CeoMeterCapability1.3.6.1.2.1.229.1.1.1.1BitsRO
TeoPowerTable1.3.6.1.2.1.229.1.2NA
ReoPowerEntry1.3.6.1.2.1.229.1.2.1NA
CeoPower1.3.6.1.2.1.229.1.2.1.1Integer32RO0
CeoPowerNameplate1.3.6.1.2.1.229.1.2.1.2Unsigned32RO0
CeoPowerUnitMultiplier1.3.6.1.2.1.229.1.2.1.3UnitMultiplierRO0
CeoPowerAccuracy1.3.6.1.2.1.229.1.2.1.4Integer32 (0..10000)RO0
CeoPowerMeasurementCaliber1.3.6.1.2.1.229.1.2.1.5INTEGERROunavailable(1)
CeoPowerCurrentType1.3.6.1.2.1.229.1.2.1.6INTEGERROac(1)
CeoPowerMeasurementLocal1.3.6.1.2.1.229.1.2.1.7TruthValueRO1
CeoPowerAdminState1.3.6.1.2.1.229.1.2.1.8PowerStateSetRW259
CeoPowerOperState1.3.6.1.2.1.229.1.2.1.9PowerStateSetRO259
CeoPowerStateEnterReason1.3.6.1.2.1.229.1.2.1.10OwnerStringRWunknown
TeoPowerStateTable1.3.6.1.2.1.229.1.3NA
ReoPowerStateEntry1.3.6.1.2.1.229.1.3.1NA
CeoPowerStateIndex1.3.6.1.2.1.229.1.3.1.1PowerStateSetNA257
CeoPowerStateMaxPower1.3.6.1.2.1.229.1.3.1.2Integer32RO0
CeoPowerStatePowerUnitMultiplier1.3.6.1.2.1.229.1.3.1.3UnitMultiplierRO1
CeoPowerStateTotalTime1.3.6.1.2.1.229.1.3.1.4TimeTicksRO68956304 (7d 23h 32m 43s)
CeoPowerStateEnterCount1.3.6.1.2.1.229.1.3.1.5Counter32RO8
TeoEnergyParametersTable1.3.6.1.2.1.229.1.4NA
ReoEnergyParametersEntry1.3.6.1.2.1.229.1.4.1NA
CeoEnergyParametersIndex1.3.6.1.2.1.229.1.4.1.2Integer32 (1..2147483647)NA
CeoEnergyParametersIntervalLength1.3.6.1.2.1.229.1.4.1.3TimeIntervalRC
CeoEnergyParametersIntervalNumber1.3.6.1.2.1.229.1.4.1.4Unsigned32RC
CeoEnergyParametersIntervalMode1.3.6.1.2.1.229.1.4.1.5INTEGERRC
CeoEnergyParametersIntervalWindow1.3.6.1.2.1.229.1.4.1.6TimeIntervalRC
CeoEnergyParametersSampleRate1.3.6.1.2.1.229.1.4.1.7Unsigned32RC
CeoEnergyParametersStorageType1.3.6.1.2.1.229.1.4.1.8StorageTypeRC
CeoEnergyParametersStatus1.3.6.1.2.1.229.1.4.1.9RowStatusRC
TeoEnergyTable1.3.6.1.2.1.229.1.5NA
ReoEnergyEntry1.3.6.1.2.1.229.1.5.1NA
CeoEnergyCollectionStartTime1.3.6.1.2.1.229.1.5.1.1TimeTicksNA
CeoEnergyConsumed1.3.6.1.2.1.229.1.5.1.2Unsigned32RO
CeoEnergyProvided1.3.6.1.2.1.229.1.5.1.3Unsigned32RO
CeoEnergyStored1.3.6.1.2.1.229.1.5.1.4Unsigned32RO
CeoEnergyUnitMultiplier1.3.6.1.2.1.229.1.5.1.5UnitMultiplierRO
CeoEnergyAccuracy1.3.6.1.2.1.229.1.5.1.6Integer32 (0..10000)RO
CeoEnergyMaxConsumed1.3.6.1.2.1.229.1.5.1.7Unsigned32RO
CeoEnergyMaxProduced1.3.6.1.2.1.229.1.5.1.8Unsigned32RO
CeoEnergyDiscontinuityTime1.3.6.1.2.1.229.1.5.1.9TimeStampRO
NenergyObjectMibConform1.3.6.1.2.1.229.2
NenergyObjectMibCompliances1.3.6.1.2.1.229.2.1
MenergyObjectMibFullCompliance1.3.6.1.2.1.229.2.1.1
MenergyObjectMibReadOnlyCompliance1.3.6.1.2.1.229.2.1.2
NenergyObjectMibGroups1.3.6.1.2.1.229.2.2
GenergyObjectMibTableGroup1.3.6.1.2.1.229.2.2.1
GenergyObjectMibStateTableGroup1.3.6.1.2.1.229.2.2.2
GenergyObjectMibEnergyParametersTableGroup1.3.6.1.2.1.229.2.2.3
GenergyObjectMibEnergyTableGroup1.3.6.1.2.1.229.2.2.4
GenergyObjectMibMeterCapabilitiesTableGroup1.3.6.1.2.1.229.2.2.5
GeoPowerEnableStatusNotificationGroup1.3.6.1.2.1.229.2.2.6
GenergyObjectMibNotifGroup1.3.6.1.2.1.229.2.2.7

Textual conventions

UnitMultiplier INTEGER

atto(-18) exa(18) femto(-15) giga(9) kilo(3) mega(6) micro(-6) milli(-3) nano(-9) peta(15) pico(-12) tera(12) units(0) yocto(-24) yotta(24) zepto(-21) zetta(21)

The Unit Multiplier is an integer value that represents
the IEEE 61850 Annex A units multiplier associated with
the integer units used to measure the power or energy.

For example, when used with eoPowerUnitMultiplier, -3
represents 10^-3 or milliwatts.